What is covered
Scope
- Three-piece fluid ends in the 1,000-2,500 HHP band.
- Supplied as single pieces or as a set for one fluid end (three per pump on a triplex).
- Diameter, roundness, surface finish and hardness are recorded as measured values on each part record.
- Coating and material grade are stated on the quotation and repeated on the certificate.
Fitment
Pump families we match to
| Pump family | Pressure level | Notes |
|---|---|---|
| SPM HT-400, TWS-2000, TWS-2250 | 2,000 - 2,250 HHP | Plungers, seat and insert sets, fluid-end wear parts |
| National 1500 | 1,500 HHP | Plungers, seat and insert sets, rod packing |
| Gardner Denver C-2250 | 2,250 HHP | Plungers, seat and insert sets, fluid-end components |
| SLB FracTec | 2,000 - 2,500 HHP | Fluid-end parts, matched by OEM part number |
| F-1000, F-1300, F-1600 series | 1,000 - 1,600 HHP | Plungers, seats, inserts, packing |
Interchange is stated as same-rating interchangeable only. We confirm fit against your pump model, pressure level and OEM part number before we quote.
Commitments
Life, warranty and evidence
Plungers are the highest-frequency wear item on a frac pump, and the part where a life promise is worth the most. We do not publish a generic hour figure: Life is managed under our field-data basis, MEPH (median effective pumping hours). The figure that applies to you is the one set out in Annex A of your signed Sales Contract.
Life and warranty commitments are stated only in the Warranty Terms Sheet annexed to your Sales Contract and are subject to its caps and exclusions.
Enquiry
Ask for this line
Send the pump model, pressure level, part number and quantity, or use the form below.